power steering RENAULT SCENIC 2014 J95 / 3.G Petrol Injection - Sagem3000 Workshop Manual

Page 93 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B-93V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
FUEL CIRCUIT SUB-FUNCTION (continued 1)
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
5
Motorised
throttlePR090: Idle speed
regulation
programming
value- 12% < PR090 < 12%
PR090, an adaptive built-in action, is
a stored parameter designed to
program variation and engine ageing
for the idle speed regulator. These
are programmed only when the
engine is idling and warm, and no
electrical consumers (electrical
windscreen, air conditioning, GMV,
power steering) have been selected.
Therefore it adjusts slowly.
WITHOUT
6 PR141: Integral idling
speed
regulation
correction0%
The built-in correction is
continuously calculated to take into
account consumer air demand.
7 Motorised
throttlePR091: Theoretical
idle speed
regulation
OCR0% < PR091 < 100%
When the conditions for regulation
are met, the idle regulator continually
repositions the motorised throttle to
keep the engine speed at the idling
speed setting. The motorised throttle
opening ratio required to adhere to
the engine speed setpoint is then
given by parameter PR091.
JSAA741.0

Page 114 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B-114V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
FUEL CIRCUIT SUB-FUNCTION (continued 1)
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
5
Motorised
throttlePR090: Idle speed
regulation
programming
value- 12% < PR090 < 12%
PR090, an adaptive built-in action, is
a stored parameter designed to
program variation and engine ageing
for the idle speed regulator. These
are programmed only when the
engine is idling and warm, and no
electrical consumers (electrical
windscreen, air conditioning, GMV,
power steering) have been selected.
Therefore it adjusts slowly.
WITHOUT
6 PR141: Integral idling
speed
regulation
correction4.7% < PR141 < 32%
The built-in correction is
continuously calculated to take into
account consumer demand for air.
7 Motorised
throttlePR091: Theoretical idle
speed
regulation OCR5% < PR091 < 50%
When the conditions for regulation
are met, the idle regulator continually
repositions the motorised throttle to
keep the engine speed at the idling
speed setting. The motorised throttle
opening ratio required to adhere to
the engine speed setpoint is then
given by parameter PR091.
JSAA741.0